HOME     |      ABOUT US    |     CONTACT US     |     PRODUCTS     |     SERVICES     |      NEWS       |      SITE MAP

           
           

Electronic Handwheel EHL Technical Description

 
 
Duty Cycle: 100%
Driving Torque: 5.5 Nm at 50 rpm
2 Nm at 135rpm
Thermal Protection: 115ºC
Protection Mde: IP 20
   
   
Description of Speed Control
 
Fast Speed: The EHL is run at nominal speed (50 resp. 135 rpm.). In this case the rotary potentiometer has no function.
   
Creep Speed: By means of a rotary potentiometer the speed can be continuously adjusted (0-50 resp. 0-135 rpm) e.g. for set-up

   

Arrangement Actuator/Transformer
 
The position of drive and transformer can be modified according to individual conditions of installation (adjustable, engaging at 90º intervals). However, in this case the connecting cable has to be extended. The EHL can also be delivered according to your requirements.


Motor Adapter for Linear Units
   

   
 

Motor Adaptor for Linear Units

Code Number For Linear Unit* Pin Ø Unit A B C D E F G H L Ø
92663 E 30 8 50 50 30 40 30 30 6 67 60 30
92664 E 40 12 60 60 46 46 36 36 7 67 75 40
92665 E 50 12 65 65 46 46 - - 9 67 90 60
92666 E 60 14 80 80 55 55 46 46 9 67 110 60
92682 E 80 20 80 80 70 70 - - 6.2 59 - 80
92667 EP 30 8 50 50 30 40 30 30 6 67 - -
92668 EP40 / COPAS 40 10 60 60 46 46 36 36 7 67 - -
92669 EP 50 12 65 65 46 46 - - 9 67 - -
92670 EP 60 14 80 80 55 55 46 46 9 67 - -
92683 EP 80 20 92 92 64 64 - - 8.5 59 - -
92680 EV / AV 30 8 40 40 29 29 - - 6 67 - -
92671 EV / AV 40 10 40 40 29 29 - - 6 67 - -
92672 EV / AV 50 12 50 50 38 38 - - 7 67 - -
92679 EV 60 12 60 60 46 46 36 36 7 67 - -
92673 EV / AV 80 14 80 80 55 55 46 46 9 67 - -
92674 COPAS 20 8 46 50 30 40 - - 7 67 - -
92675 COPAS 30 10 60 60 46 46 36 36 7 67 - -
92676 PLS-II 30 6 40 40 29 29 - - 6 67 - -
92677 PLS-II 40 8 40 40 29 29 - - 6 67 - -
92678 PLS-II 50 10 50 50 38 38 - - 7 67 - -
92679 PLS-II 60 12 60 60 46 46 36 36 7 67 - -
92681 PLS-II 80 14 80 80 55 55 46 46 9 67 - -

Limit Switch  
Max. Voltage: 250 V AC
Max. Constant Current: 6 A
Max. Starting Current: 16 A
Switching Frequency: max. 6000/h
Lifetime: 1x107 switching cycles
Lever Arm Adjustment: 360º rotation
Protection Mode: IP 65
Ambient Temperature: -30ºC to +80ºC
Code Number Type
91900 NC/NO
91901 Connecting table (3m) for limit switch, incl. PG connection
   
 
   