HOME     |    ABOUT  US    |    CONTACT US    |    PRODUCTS    |    SERVICES    |    NEWS    |    SITE MAP

Technical Data

Back to Stairworks Intro Page
Technical Data and Permitted Connecting Force
 
 
Mechanical Features AlSi 12 Cu
Socket Connection Leg. 231
Tensile Strength 180-260 N/mm2
0.2 limit 90-120 N/mm2
Sbw 70-80 N/mm2
Ductile Yield 2-4%
Brinell Hardness 50-65 HB
Impact Value 5-8.5 J/cm2

  Including Static Safety Factor
v = 2.5
Including Dynamic
Safety Factor
v = 2.5
Type F Mb F Mb
FI 40 1250 N 350 Nm 1200 N 160 Nm
MI 40 1250 N 340 Nm 1200 N 160 Nm
WI 40 1250 N 200 Nm 1200 N 160 Nm
WIT 40 1250 N 200 Nm 1200 N 160 Nm
WIE 40 1250 N 200 Nm 1200 N 160 Nm
WITE 40 1250 N 200 Nm 1200 N 160 Nm

Internal Tension System

The component range of the ITAS internal tension system has been extended with some additional variations. These permit completely new construction possibilities.
     The fixation of the tube occurs through a clamping rocker/thrust pad by turning the clamping screw.


Quick Change System

The ITAS Quick Change System enables protected working or machine areas to be accessed with little manipulation and without requiring a lot of tools. The system avoids railing having to be completely dismantled e.g. for repair work.


Dismantling of Quick Change System
 


Building Regulations for Railings According to UVV, VBG1 and Conforming to DIN EN ISO 14122-3 
"Construction Type" Tested

       

Example

Dimensions [mm] max.

A B L
1 500 1000 1500*
2 500 1000 1500*
  *The support spacing "L" must ensure that 340 Nm for base fype FI40 is not exceeded.
Example 1, wall and floor fixing Example 2, self-supporting
 with floor fixing
   

       
 

Load Data

• Load data according to DIN 1055
• Maximum admitted load of steps (for a length of 1.2 m) 1500 N
• Maximum admitted load of stairs cross beams (for a 45º angle
   and  length of 4 m without support) 3500 N
• Maximum admitted load of railing (distance between pillars 
  0.7 m)  500N

• The maximum admitted load of the platform depends on the base
   construction. It cannot exceed the maximum admitted load of the base
   clamps used.
• Technical safety requirements in accordance with DIN EN ISO
   141221-4

 

Example for Horizontal Railing

Example for Stair Railing - Catwalk Connector

• The railing must have at least one knee rail
• Do not exceed a free space between the
   handrail and knee and foot rail of 500 mm
• Fit a foot rail with a minimum height of 100
  mm maximum 10 mm above the step level
A staircase must have a least one handrail. With a flight width equal to or exceeding 1200 mm two handrails must be provided in the same manner as with all ladder stairs.
  

Raised Platform and Stairs Catwalk Over Conveyor Line Custom Platform and Guard Basic Safety Rail and System
       

We have attempted to present the information on this website in a straight-forward manner. We offer this information as accurate at the time of publication. Specifications are subject to change without notice. RK Rose+Krieger is not responsible for inadvertent errors.  

©2010 Phoenix Mecano Inc., 7330 Executive Way, Frederick, MD 21704, 301-696-9400, rkinfo@pm-usa.com