Safety Distances
Distance to dangerous area for a frame 2200 mm high
acc. to EN294 (upper limbs)
and EN811 (lower limbs)
 
Safety Distances
Distance to dangerous area for a frame 1600 mm high
acc. to EN294 (upper limbs)
and EN811 (lower limbs)

   




 

 

 
ESP - Inserting Profile for Wire Mesh
 
Features:
• special profile for the insertion of wire meshes,
  (size 30 for 30x30x3, size 40 for 40x40x4)
• appealing design and easy to clean thanks to profile
   visible surfaces without long slots
• high stability through large inserting depth
 

 

 

   
Clamping Profiles The clamping strip is pressed against the surface element by means of clamping screws. Thus, sturdy fitting and problem-free absorption of tolerances in panel thickness are guaranteed.
Included in delivery: basic profile, screw (distance between bore
                                 holes approximately 200mm)
   


 

Features:
• connecting possibility for panels and wire meshes
   which ensures sturdy fitting without clattering
• appealing design and easy to clean thanks to profile
   visible surfaces without long slots
• version with different angle gradation for varying
   applications
• panels from 3 mm up to 10 mm thick can be installed
  without any further complicated accessories

 
 
• clampable panel thickness:
  size 30 3 to 6 mm
  size 40 0 to 10 mm
• panel depth allowances on all sides:
  size 30 +10 mm
  size 40 +15 mm
 
Modular System
 
The modular system concentrates on essential aspects i.e. the protective function and the assembly with minimum time expenditure.
 
Features:
• easy, quick assembly directly on site
• rapid assembly and disassembly of single frames
  e.g. for machine maintenance
• can be assembled at any desired angle and is
   therefore optimally adjustable to any particular
   condition
• frames with the same lattice dimensions are
   interchangeable
Widths: center-to-center distance between the pillars
Heights: total height
 

 

*referring to pillar profile 50. When using pillar profile S-40 add respectively 10 mm to the surface width.


 

Proceeding
 
1. Planning
 
a) Fix the required lengths
Example: a machine measuring 5.50m x 3.50m must be provided with a protection system. Considering the safety distances the results is a rectangle of approx. 6m x 4m.
 
b) Now, with the aid of different module dimensions the design of the protection system can be fitted for particular requirements. In our example we adopted the following solution:
4 m side = 2 x 2.0 m module
6 m side = 4 x 1.5 m module
Number of pillars = 12
 
 
 

 

 


   
Material Requirements a) different frame versions with varying surface elements are
   shown
  b) furthermore, hinged doors, sliding doors and vertical-lift
    doors are available to be also applied to the modular
    system
  c) there are two different types of pillars:
      protection system = pillar with base clamp (type 1 and 2)
      partitioning system = pillar with base plate (type 3)
   


Pillar
 
consists of pillar profile 50 / S-profile 40 / F-profile-50
• pedestal version at your choice
 
 
 
   
Application
 
 

 

 


Type 1 FFV


Type 2 FVA
for pillar profile 50,
F-50


Type 3 FP
for pillar profile 50,
F-50, S-40

 
  
 

We have attempted to present the information on this website in a straight-forward manner. We offer this information as accurate at the time of publication. Specifications are subject to change without notice. Rose+Krieger is not responsible for inadvertent errors.  

©2010 Phoenix Mecano Inc., 7330 Executive Way, Frederick, MD 21704, 301-696-9400, rkinfo@pm-usa.com